Home > Because Of > Because Of Ipc Error Timeout. Disabling Line Card

Because Of Ipc Error Timeout. Disabling Line Card

I used VRRP for my internal nework and failover have been tested working.Even tried to remove link of 7204-A and 7609, the failover works perfect. show trace - On bootup, the LP tests its blade and reports the status back to the RPM. Here is my running config prior to adding the options in the above link: http://pastebin.com/AgNb1ahG Thank you for any help! Reply With Quote 0 03-08-2011,04:50 AM #11 RyanD View Profile View Forum Posts View Forum Threads Visit Homepage Managed Service Provider Join Date Feb 2004 Location Atlanta, GA Posts http://onlinetvsoftware.net/because-of/because-of-ipc-error-timeout.php

It also occurs after a line card is removed and reinserted within a very short time period, confusing the polling logic which expects a certain sequence of events. Advertisement Web Hosting News QTS Appoints Its First Cybersecurity Chief Why Rackspace is Going Private, According to Its CTO Rackspace Going Private in $4.3B Buyout ZENEDGE Launches Single IP Protection at You may have to register before you can post: click the register link above to proceed. Messagenot sent due to [chars].

This condition occurs when the line card CPU's request to receive a local operating system image is not received by the RPM's control processor. Message not sent due to timeout. Disabling linecard. (Expected during linecard OIR)Explanation: A general IPC related error occurred which may prevent transferof data to other peers using the IPC mechanism.Recommended Action: Get the output of the show Cisco WAN :: Install Second SUP-engine In 7609?

The messages appeared on the console and in the output of the show logging command. %RPM0-P:RP2 %VRRP-6-VRRP_MASTER: vrid-1 on Vlan 308 entering MASTER. The answers are in the IOS errors - eXternal Data Representation - XDR - used by IPC for RP-to-RP and RP-LC communication failed to allocate memory to XDR which was probably Is it possible for you to open a TAC case?Thanks,Richard See More 1 2 3 4 5 Overall Rating: 0 (0 ratings) Log in or register to post comments Ali Norouzi See the separate document, Troubleshooting Card Shutdowns Due to High Temperature.

Eninja On Apr 30, 2009, at 5:32 PM, Phil Mayers wrote: > All, > > We have a chassi with 2x sup720-3B and running SXI that, for the F10#dir flash: Directory of flash: 1 drwx 2048 Jan 01 1980 00:00:06 CRASH_LOG_DIR 2 drwx 2048 Sep 06 2028 02:01:28 TRACE_LOG_DIR 3 drwx 2048 Sep 06 2028 02:01:28 NVTRACE_LOG_DIR 4 -rwx Searchfor resolved software issues using the Bug Toolkit at »www.cisco.com/pcgi-bin/S ··· gtool.pl.If you still require assistance, open a case with the Technical Assistance Centervia the Internet at »tools.cisco.com/ServiceR ··· l/create, or the cpu utilisation can rise 99% et this is usually.

I did not find any proper configuration example. TAC advised a bunch of stuff that basically amounted to re-seating the card, failing over to the sup to see if the sup or software was faulty (yikes...), swapping the sups Research and attempt to resolve theissue using the tools and utilities provided at »www.cisco.com/tac. Register Now, or check out the Site Tour and find out everything Web Hosting Talk has to offer.

log keyword is configured in access-list and traffic go through the member switches hit access-list that log keyword is configured. Learn More About Cisco Service Contracts Information For Small Business Midsize Business Service Provider Executives Industries Automotive Consumer Packaged Goods Education Energy Financial Services Government Healthcare Hospitality Life Sciences Manufacturing Materials F10#show trace | find 1/3 [1/3 0:12:9] RAM-(RpmAvailMgr):Get peer RPM control messages from peer RAM. [1/3 0:12:9] RAM-(RpmAvailMgr):ramProcessPeerControlMsg: Receiving msg: RPM_STANDBY_FAULT_NOTIFY. [1/3 0:12:9] RAM-(RpmAvailMgr):Succeded to reboot Peer RPM by using f10SysRpmMasterResetPeer Message not sent due to timeout.

Events Events Community CornerAwards & Recognition Behind the Scenes Feedback Forum Cisco Certifications Cisco Press Café Cisco On Demand Support & Downloads Community Resources Security Alerts Security Alerts News News Video Set LC_LED_SOLID_GREEN show tech-support command output. CRC errors are recorded on a Gigabit Ethernet interface Bad fiber cables and dirty optical transceivers have been shown to generate CRC errors. or not, to take effect same functional on C7609, what is the command for that?

Attach the following information to your casein nonzipped, plain-text (.txt) format: the output of the show logging and showtech-support commands and your pertinent troubleshooting logs.%XDR-6-XDRIPCNOTIFY (x0): Message not sent to slot The show linecard {slot#} command reports “Status : booting - line card port pipe problem”. Edge 1, LLC http://www.edge1.net | 800.392.2349 Cisco SMARTnet & Licensing Specialists | Datacenter/Network Design & Management Consulting | Cisco New & Certified Refurb Equipment Sales Reply With Quote 0 Attach the following information to yourcase in nonzipped, plain-text (.txt) format: the output of the show logging andshow tech-support commands and your pertinent troubleshooting logs.%XDR-6-XDRIPCNOTIFY (x0): Fatal IPC error occurred for

With somemessages, these tools and utilities will supply clarifying information. Thank you all for the help! Disabling linecard. (Expected during linecard OIR)Explanation: A general IPC-related error has occurred that may prevent transferof data to other peers using the IPC mechanism.Recommended Action: Enter the show xdr multicast and

Registered users can view up to 200 bugs per month without a service contract.

Nothing has changed on the RemoteApp server side, only the upgrade to 8.4. Below is list modules and then the logs:rtr-019#sh moduleMod Ports Card Type                              Model              Serial No.--- ----- -------------------------------------- ------------------ -----------  1   24  CEF720 24 port 1000mb SFP              WS-X6724-SFP       SAL1048958X  3    4  CEF720 There are some similar-sounding messages in the SXI release notes, but we've got other identically-configured boxes that don't display these symptoms, so I'm fearing a hardware fault (which would be ironic Copy the message exactly as it appearson the console or in the system log.

Research and attempt to resolve theissue using the tools and utilities provided at »www.cisco.com/tac. View 3 Replies View Related Cisco WAN :: Setting Up A New VRF On 7609? As your next step in collecting data, capture the output of the show trace command for your system. ======================================================================= Force10 Application Software Version: 6.2.1. [10/1 15:58:35] CHMGR-(chmgr):lc 0 has unexpectedly powered Cisco WAN :: Upgrading A 7609 12.2 To 15.X Cisco WAN :: QOS On Router 7609 Cisco WAN :: 7609 / MPLS Over GRE Tunnels?

Bug Details Include Full Description (including symptoms, conditions and workarounds) Status Severity Known Fixed Releases Related Community Discussions Number of Related Support Cases Bug information is viewable for customers and partners I was able to get NetFlow exporting data if I didn't export peer-as data. Contact Gossamer Threads Web Applications & Managed Hosting Powered by Gossamer Threads Inc. The answers are in the IOS errors - eXternal Data Representation - XDR - used by IPC for RP-to-RP and RP-LC communication failed to allocate memory to XDR which was probably

See the separate document, Troubleshooting a “card out of contact or in reset” Condition. Bug details contain sensitive information and therefore require a Cisco.com account to be viewed. The issue will NOT happen if we power all 6 switches together View Bug Details in Bug Search Tool Why Is Login Required? The config looks very different after the upgrade plus what looks to be duplicate entries. I suspect its an access list issue but I'm not sure. hostname ciscoasadomain-name default.domain.invalidenable password NvZgxFP5WhDo0hQl encrypted[Code].....

The following information is essential to determine the cause of a line card problem: show trace command output on the RPM for the line card with the issue. Wrote 630048 bits: 135014 ones, 495034 zeros... Attach the following information to yourcase in nonzipped, plain-text (.txt) format: the output of the show logging andshow tech-support commands and your pertinent troubleshooting logs.%XDR-6-XDRIPCNOTIFY (x1): Fatal IPC error occurred for Bout f%#@n time Apple! [Apple] by onebadmofo332. $199 technician fee to retain 300mbps service if cancelling TV [TimeWarnerCable] by enkur2296.

Upon reccurence, please collect crashinfo, "show tech" and contact Cisco Technical Support. In each7609 we have a 24 port channelized T1 Circuit Emulation Over Card.The requirement is in 2 parts. I have 7609 routers. Or Atfer do this,I reload the router on active engine directly?

The output currently is designed for analysis by Force10 development engineers only Information to Collect if You Open a TAC Case To request assistance from Force10 Networks after following the View 2 Replies View Related Ethernet Access Not Working After Windows 8 Upgrade?