Std = Spa operating in Standard Mode. It did at that point flash up F2 before the OH came up. Back to Top Ecn or Ec Message Ecn or Ec MessageIf the Ecn or Ec Message is Alternating with the Water Temperature on the Display, the Spa is Operating in the SnS = Sensors out of balance. navigate here

If display shows only this message (blinking) spa is shut down. Pump doesn't even get chance to come on OH flashing. Then power the system back up, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off. Sn2 = Nonfunctional temperature sensor.

Balboa Sns Error Code

Back to Top rdr or DRAIN WATER Message Time to "Drain Spa Water Reminder" (rdr).Appears Every 90 Days*. FREE SHIPPING $100+ $0.00 SIGN IN Sign In Registered Customers SIGN IN Forgot Password? Turn OFF the Power to the System and Turn it back ON again to put System into Priming Mode.2. If the Spa with the "SF" Safety Fault Error Message has a pump suction blockage switch, Select "Spas with Pump Suction Blockage Switch" Below.

Back to Top rCA or CHANGE MINERAL CARTRIDGE Message Time to "Change Mineral Cartridge Reminder" (rCA)Install a New Mineral Cartridge per Manufacturers Instructions. Q. I have had the sensors off and on the board a few times. Balboa High Limit Switch Location There is no guarantee expressed or implied that this technology can detect all instances of a real or potential problem with the equipment.

Spa Error Codes: Sn, Sn2, Sn3, EO, E1, Prr With these spa sensor codes, the Temperature Sensor is open or shorted. If alternating with temp, may be temporary condition. COOL = Spa water is more than 20┬░ F cooler than the temperature set point. To read the Current Water Temperature, either Change to Standard Heating Mode or turn On the Heating Related Pump, and wait at least 2 Minutes.

This list if far from complete and covers older model controls. '- -' Temperature Unknown 'Cool' Water temp 20 ░ below set point 'dr' Possible inadequate Balboa Hot Tub Error Codes There was no corrosion. Note: Internal freeze protection only functions when there is proper power running to the spa, and the control system is operational. Heat Related Pump Not Running.8.

Arctic Spa Hl Error Code

I put a ohm meter on pressure switch to test continuity which it didn't... Maybe when I swapped the sensor set I didn't push it back on properly? Balboa Sns Error Code Logged Arctic Spas Dealer of the Year- 2012, 2011, 2010, 2009 Hot Tub Forum Re: HL reading « Reply #10 on: January 03, 2009, 07:06:12 PM » Print Pages: [1] « Hl Error Code Hot Tub Check for Water Level, Flow Restrictions, Closed Valves, Air Bubbles, and Pump Prime, or contact your Dealer or Service Organization.Check for All of the following Conditions:1.

Press any button to reset after the problem has been corrected, or or contact your Dealer or Service Organization. 1. http://onlinetvsoftware.net/error-code/005-122-error-code.php Turn the power back on. Its a 2 speed pump.. Balboa start up codes then OH starts flashing immediately before any pumps/jets have even had chance to come on. Balboa High Limit Sensor

  1. FLO2 = Closed or shorted flow switch on system startup Dream Maker Spa Side Error Codes OH = Overheat 108┬░ F, spa is deactivated.
  2. LF = Persistent low flow problems. (Displays on the 5th occurrence of "HFL" message with 24 hours).
  3. Too Many Closed Jets.6.
  4. It may be possible for the stuck relay to free itself after the power cycle, but the spa cannot clear the the HOt message without starting up in Test Mode first.
  5. The Water Temperature will probably drop Below Set Temperature between Filter Cycles.
  6. Back to Top rCH or NEW FILTER Message Time to "Change Filter Reminder" (rCH)Appears Every 365 Days*.
  7. Back to Top SbY or STANDBY MODE Message The Spa is Operating in the "Standby" (SbY) Mode.All Automatic Spa System Functions are Disabled so that Pumps and Blower will not turn
  8. Hope all that helps.

Startup codes followed by OH flashing! Dirty Filter.5. The sensor that is plugged into the sensor "A" jack is not working 'Sb' Spa is shut down. his comment is here Why isn't the system maintaining the set temperature of the water?

It automatically activates the pump (and the heater if necessary) to circulate the water and warm the plumbing. Balboa Spa Control Manual Even OHM-ing out thermistors is not 100% accurate 100% of the time in determining what has failed. If tripping continues, call for service.• Deactivate spa lock Hercules Control Systems for Spas or Hot Tubs: OH = Spa temp exceeds acceptable limits FLO = Flow problem ICE = Freeze

Back to Top - - F, - - C, or - - Message The Actual Water Temperature is "Unknown" (- -).Priming Mode has been Exited and the Pump has Not yet

It's easy! Balboa (used by Belize Spas and many other hot tubs) pd = Power supply, unit running on battery backup OH = Sensors reading 112-118┬░ F. Low Water Level.2. Balboa Hot Tub Codes Sl These error codes are caused by a variety of reasons.

Heater Start Up will begin again after about 1 Min. Try this: Turn off the power. No more HL reading which is good. weblink I did test both the hi-limit and temp sensor with a multimeter ohm tester and got readings of Hi-limit - 57.6 Temp - 55.8 Whilst everything was cold.

Sensor plugged into jack A is not working.Snb = Spa is shut down. Rare system error. Snb = Spa is shut down. Test and Adjust pH Level per Manufacturers Instructions.

Spa is shut down. PSoL = Pressure switch open with low pump. Check for Water Level, Flow Restrictions, Closed Valves, Air Bubbles, and Pump Prime, or contact your Dealer or Service Organization.Check for All of the following Conditions:1. It's not the M7 balboa where there is 2 temp sensors going into the heater.

Common Spa Panel Messages - - - or - - Message - - F, - - C, or - - Message CFE or CONFIG ERROR Message CrC or CHKSUM FAIL Message The sensor that is plugged into the sensor "B" jack is not working 'SE' Spa operating in Standard-in-Economy Mode. 'SL' or 'SLP' ( The following is not a Error Make sure that all jets are open, and nothing is blocking the spa drain cover flow. OHH = Overheat.

Contact your Dealer or Service Organization to check the Switch Numbers or Setting Values Displayed, and Correct as Necessary to Match the Equipment in the Spa System, or Continue for a Then re-start the hot tub, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off. The Heater will Only operate and Heat up to Set Temperature during the Filter Cycles. Press "Mode" Button to Clear Message.

In most cases overheat issues are related to the relays on the circuit board, or the temp sensor has failed and will need to be replaced. Is that a board? Logged bosco0633 Senior Member Posts: 1257 Look into my eyes Re: HL reading « Reply #6 on: January 03, 2009, 06:39:00 PM » and this is the strange this. HFL = Substantial difference between temperature sensors detected.

Low Water Level.2. Logged Summitman Full Member Posts: 423 Re: HL reading « Reply #8 on: January 03, 2009, 06:51:21 PM » Quoteand this is the strange this. áThe tub temp actually dropped 5 SESH = Sensor short, nonfunctional.